CSC 240 - Network Fundamentals » Summer 2021 » Module 1 Week 2.4.8

Need help with your exam preparation?

Question #1
Which pins in an RJ45 connector are used to transmit data when used on a 100BaseT Ethernet network?
A.   Pin 7 and Pin 8
B.   Pin 3 and Pin 4
C.   Pin 1 and Pin 2
D.   Pin 5 and Pin 6
Question #2
Which recommendation should you follow while using 110 blocks for connecting Cat 5 and higher data cables?
A.   Connect wires using the T568B standard.
B.   Connect wires using the T568A standard.
C.   Use C-5 connectors.
D.   Keep wire pairs twisted up to within one-half of an inch of the connector.
Question #3
You are building network cables and attaching RJ45 connectors to each end. Which tool do you need for this task?
A.   Needle nose pliers
B.   Crimping tool
C.   Punch down tool
D.   Wire puller
Question #4
You are working with 25 pair wires and 66 blocks. You have pushed the wires onto the 66 block, but now you need to cut off the excess end of each wire. Which tool should you use?
A.   Cable stripper
B.   Needle nose pliers
C.   Snips
D.   Punch down tool
Question #5
You want to use the T568B standard for adding connectors to your Cat5 cable. Starting with pin 1, which order should you use for the wires within the connector?
A.   White/green, green, white/orange, blue, white/blue, orange, white/brown, brown
B.   White/blue, blue, white/orange, orange, white/green, green, white/brown, brown
C.   White/orange, orange, white/green, blue, white/blue, green, white/brown, brown
Question #6
Which of the following methods would you use to create a crossover cable?
A.   Use the T568A standard on one connector and the BLOG convention on the other connector.
B.   Use the T568B standard on one connector and the BLOG convention on the other connector.
C.   Use the BLOG convention.
D.   Use the T568A standard.
E.   Use the T568A standard on one connector and the T568B standard on the other connector.
Question #7
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568B standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 1
A.   Solid orange
B.   White with orange stripe
Question #8
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568B standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 2
A.   Solid orange
B.   Solid brown
Question #9
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568B standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 3
A.   White with green stripe
B.   White with brown stripe
Question #10
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568B standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 4
A.   Solid blue
B.   Solid green
Question #11
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568B standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 5
A.   Solid orange
B.   White with blue stripe
Question #12
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568B standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 6
A.   Solid green
B.   White with green stripe
Question #13
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568B standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 7
A.   White with brown stripe
B.   Solid blue
Question #14
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568B standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 8
A.   Solid orange
B.   Solid brown
Question #15
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568A standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 1
A.   White with green stripe
B.   Solid brown
Question #16
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568A standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 2
A.   White with brown stripe
B.   Solid green
Question #17
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568A standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 3
A.   Solid orange
B.   White with orange stripe
Question #18
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568A standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 4
A.   White with blue stripe
B.   Solid blue
Question #19
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568A standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 5
A.   White with green stripe
B.   White with blue stripe
Question #20
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568A standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 6
A.   Solid green
B.   Solid orange
Question #21
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568A standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 7
A.   White with brown stripe
B.   White with orange stripe
Question #22
You need to terminate a Cat 6 UTP cable with an RJ45 connector. Your organization's IT policy states that all cable connectors must be wired according to TIA568A standards. Select the UTP wire to the correct pin in the RJ45 connector. Pin 8
A.   Solid blue
B.   Solid brown
Question #23
Which of the following is used to terminate individual wires from a 25 pair or 100 pair cable using female RJ45 ports?
A.   66 block
B.   Patch panel
C.   110 block
D.   Horizontal cross connect
Question #24
Which of the following describes the point where the service provider's responsibility to install and maintain wiring and equipment ends, and the customer's responsibility begins?
A.   Demarc
B.   Vertical cross connect
C.   IDF
D.   Punch down block
Question #25
You have a network that occupies all three floors of a building. The WAN service provider has installed the line for the WAN service into the building in a wiring closet on the main floor. You have a wiring closet on the two remaining floors directly above the wiring closet on the main floor. What would you use to connect the wiring closets together?
A.   Demarc extension
B.   Horizontal cross connect
C.   Smart jack
D.   Vertical cross connect
Question #26
Which of the following terms identifies the wiring closet in the basement or a ground floor that typically includes the demarcation point?
A.   MDF
B.   IDF
C.   Smart jack
D.   110 block
E.   Horizontal cross connect
Question #27
You have a network that occupies both floors of a building. The WAN service provider has installed the line for the WAN service in a wiring closet on the main floor. You have a second wiring closet on the second floor directly above the wiring closet that holds the demarc. Which of the following terms describes the closet on the second floor?
A.   Demarc extension
B.   MDF
C.   Horizontal cross connect
D.   Vertical cross connect
E.   IDF

Need help with your exam preparation?